The Hi-Tech Lamps HBX 76 power supply operates Electronic Control System for Xenon and Mercury Lamps with onboard Igniter.
Output Power: 100-300W
Input Voltage: 90-264V AC
Lamp type: XBO, Cermax, CeraLux
INPUT DATA |
|
|
|
|
|
Nominal Operation |
Symbol |
Unit |
Nominal |
Tolerances |
Remarks |
Input voltage AC-Line | U | V AC | 100 - 240 | 90 - 264 | |
System wattage | Pu | W | 140 | 60-145 | Depends on select |
Input current | Iu | A | 0.22 - 1.65 | Depends on select | |
Line frequency | Fin | Hz | 50/60 | 47 - 63 | |
Line power factor | PFC | 1 | 1.0 | 0.92 - 1.0 |
OUTPUT DATA |
|
|
|
|
|
Ignition |
Symbol |
Unit |
Nominal |
Tolerances |
Remarks |
Ignition voltage | Uign | KVpeak | ± 14 | ± 12 - ±17 | Load capacity < 20 pF |
Ignition time | tign on | sec. | 1 | 0.9 -1.1 | |
Maximum cable length between ballast and lamp
|
Imax | mm | 240 | max. 300 | Open ends |
Nominal Operation |
|||||
Lamp voltage | ULa | V | 7.4-45 | ± 5% | Depends on lamp select |
Lamp wattage | PLa | W | 50,75,100 | ± 2% | Selectable 50, 75, 100 |
Lamp current | ILa | A | Depend on select | ||
End-Of Life-Cut off voltage | ULa, max | V | 45 | ± 2 V | |
End-Of Life-Cut off time | tEOL-Off | S | <0.2 | ||
HF-Ripple of output power | ∆PLa, rip/ PLa | % | <3 p-p | 7.4V-45V |
LIFETIME DATA - All values for Uu = 230Vrms. Temperature at test point = 70°C |
|
|
|
||
|
Symbol |
Unit |
Nominal |
Tolerances |
Remarks |
Ballast lifetime | tLife | H | 25.000 | >25.000 | Acc. To MIL HDBK for nominal operation |
GEOMETRY AND WEIGHT |
|||||
Symbol |
Unit |
Nominal |
Tolerances |
Remarks |
|
Length x width x height | L x W x H | mm | 128 x 86 x 41 | ||
Housing | Closed case Al- U-profile | ||||
Weight | WB | kg | 0.41 | ECS 100 DC-y (incl. igniter) |